Alpha, Beta, Gamma

The sensors we’re using are very sensitive and pick up Apha, Beta and Gamma radiation which is different for some equipment and published readings which sometimes eliminate Alpha all together, or focus specifically on high energy Gamma. We’ve created some filters that block different kinds of radiation so we can break down our measurements and be specific as needed. Here’s an example of some breakouts of an elevated reading from our most recent trip to Sukagawa-shi, Fukushima Prefecture.

Here are the readings:
RDTN Probe 0001 Japan
5151 CPM – Unfiltered, includes Alpha, Beta and Gamma
RDTN Probe 0001 Japan
2614 CPM – Using paper as a filter to block Alpha, showing only Beta and Gamma
RDTN Probe 0001 Japan
1287 CPM – Using a few sheets of aluminum foil to block Alpha and Beta, showing only Gamma
RDTN Probe 0001 Japan
724 CPM – Using lead to block Alpha, Beta and low energy Gamma, showing only high energy Gamma私達が使用しているセンサーは非常に感度が高く、アルファ線、ベータ線、ガンマ線を感知します。これは他のいくつかの機器と異なる点であり、また公開されているいくつかの測定値とも異なる点です(公開されている測定値の中には、アルファ線が完全に排除されているデータ、または高エネルギーガンマ線のみを測定したデータがあります)。私達は、必要に応じて測定値の内容を分析しその内容を明らかにするために、異なる種類の放射線を遮断するフィルターを作成しました。以下の例は、つい先日訪れた福島県須賀川市で計測された高い測定値の内容を測ったものです。

これらがその測定値です。
RDTN Probe 0001 Japan
5151 CPM:フィルターをかける前の数値で、アルファ線、ベータ線、ガンマ線を含みます。
RDTN Probe 0001 Japan
2614 CPM:アルファ線を遮断するためにフィルターとして紙を使い、ベータ線とガンマ線のみを測ったものです。
RDTN Probe 0001 Japan
1287 CPM:アルファ線とベータ線を遮断するためにアルミホイルを数枚使用し、ガンマ線のみを測ったものです。
RDTN Probe 0001 Japan
724 CPM:アルファ線、ベータ線、低エネルギーガンマ線を遮断するために鉛を使用し、高エネルギーガンマ線のみを測ったものです。